Product Description
White Rodgers 50M56U-751 NEW-Direct Replacement Integrated Furnace Control For Carrier Single Stage HSI Controls with 120V Ignitors. Replaces Carrier 325878-751, HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016, HK42FZ034
- System Diagnostic LED With Fault Recall
- Low-Speed Continuous Fan Option
- 120 VAC Ignitor Output
- 120 or 24 VAC Humidifier output
- 120 VAC Electronic Air Cleaner Output
- Self Test Installation Routine
Pre-Purge | 30 |
Ignitor Warm-Up (1st 64 attempts) | 17 |
Maximum Ignitor Warm-Up | 19 |
Ignition Activation Period | 2 |
Trial For Ignition Period | 4 |
Recycles | 3 |
Retries | 2 Times |
Valve Sequence Period | 12 |
Interpurge | 60 |
Post-Purge | 25 |
Lockout Time | 275 |
Heat Delay To Fan On* | 25/60 |
Heat Delay To Fan Off* | 90/120 |
Cool Delay To Fan On | 2 |
Cool Delay To Fan Off* | 5/90 |
Auto Reset | 60 Minutes |
*These times will vary depending on option switch position.
See OPERATION section for further information.
Replaces
- Carrier
- 325878-751
- HK42FZ004
- HK42FZ007
- HK24FZ008
- HK42FZ009
- HK42FZ011
- HK42FZ013
- HK42FZ016
- HK42FZ034
- White Rodgers
- 50M56-751
- ICM
- ICM282A
"