Product Description
NEW-Universal Replacement Defrost Control For Single Stage PSC Fan Heat Pump Systems. Compatible With “O” Or “B” Reversing Valves. Configurable For Demand, Or Time/Temp Defrost Routines. Unique 8x8 LED Matrix Display For Configuring Menu Options and Advanced Diagnostics. Quick OEM Setup Menu, 24V Brownout Protection, High And Low Pressure Switch Inputs, Random Start Delay, Low Temp Compressor Cutout, Aux Heat Lockout, Programmable Short Cycle Delays, Reversing Valve Shift Delays. Replaces 200+ Controls
Universal
- Selectable Demand or Timed Defrost
- O or B Reversing Valve with Shift Delay
- Configures to any system
Easy Installation and Set Up
- Universal mounting with rotating display
- One-Button Configuration to Any OEM System
- Includes outdoor sensors
- Test button for system verification
Versatile Matrix Display
- Access set up and diagnostic menus from any orientation
System Protection and Diagnostics
- Brownout and short-cycle protection plus hi/low pressure inputs
- Fault recall
Auxiliary Heat Lockout
- Above the selected temperature, auxiliary heat will only run during defrost operation.
- Selectable from from 0° to 40°F or off*.
- Below the selected temperature the compressor does not operate, except in defrost cycle.
- Selectable from -10°F to 45°F or off*.
- Limit excessive noise in and out of a defrost cycle.
- Selectable 0, 12 or 30* second delay.
- 0, 3 or 5* minute selectable delay between cycles to extend the life of the compressor.
- Auto shut off when control voltage drops below 16 VAC for more than 4 seconds. Selectable on* or off.
Random Start Delay
- Delays operation for random delay after power outage to protect the compressor and avoid brownouts.
- Selectable on* or off.
- All timing is accurate to +/- 5% of nominal over the full temperature and voltage range at 60 Hz.
- All timings are 20% longer when operated with 50 Hz power supply.
- 47D01U-843 Universal defrost control with plastic mounting tray
- Thermostat harnesses: one harness with spade terminals and an optional harness with stripped leads are provided to simplify thermostat connections
- Harness #2: used to connect reversing valve, contactor, low and high pressure switches
- New Thermistors: used to measure coil temperature and air temperature – best practice to replace these when installing a new defrost control.
- Bag of accessories: 2 mounting screws, wire ties, wire nuts and labels
Electrical Ratings
Control Voltage: 24 VAC 50/60 Hz
Line Voltage: 208/240 VAC 50/60 Hz
Input Ratings:
@ 120 VAC
Compressor Coil: 24 VAC
Aux Heat (D|W|X2): 24 VAC
Reversing Valve: 24 VAC
Operating Temperature Range
-40° to 150° F (-40° to 65° C)
Humidity Range
0-95% relative humidity, non-condensing
Dimensions / Mounting
5.75"W x 4.72“L x 1.75" H