Product Description
Honeywell R8182D1079 Combination Protectorelay and Hydronic Heating Control. Vertical mountOverview
Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems.
Features
- Use in intermittent ignition applications.
- Capable of zone control with zone valves.
- Circulator zone control with ZC and ZR terminals on R8182D,E,H,J. 8*Flame failure during the running cycle results in a 45 second attempt to restart.
- If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted.
- R8182D,E,F mount directly on burner; R8182H,J mount on 4 x 4 in. junction box and include 5 ft (1.5 m) armored capillary with remote sensor.
- C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.
Product Specifications | |
Hazmat Information | UN1294 Toluene |
Dimensions (in.) | 7 1/8 in. high x 5 1/4 in. wide x 3 7/16 in. deep. |
Dimensions (mm) | 181 mm high x 133 mm wide x 87 mm deep. |
Maximum Safe Operating Pressure (psi) | 200 psi on immersion well; 100 psi direct immersion. |
Maximum Safe Operating Pressure (kPa) | 1378 kPa on immersion well; 90 kPa direct immersion. |
Temperature Range (F) | Maximum--250 F at element |
Temperature Range (C) | Maximum--121 C at element |
Includes | Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case. |
Mounting | Vertical Mount |
Frequency | 60 Hz |
Approvals, Underwriters Laboratories Inc. | UL Listed: File No. listed: MP268, Vol. 3,4 (R8182D,E,F), Vol. 37 (R8182H,J), Sec. 1. |
Approvals, Canadian Standards Association | Certified: File No. LR95329-1 |
Tradeline Value | Tradeline |
Operating Humidity Range (% RH) | 0 to 95% RH, non-condensing |
Power Consumption | 9 W |
Voltage | 120 Vac |
Operating Temperature Range (F) | High Limit-- 130 F to 240 F; Low Limit-- 110 F to 220 F |
Operating Temperature Range (C) | High Limit-- 54 C to 116 C; Low Limit-- 43 C to 104 C |
Differential Temperature (F) | High limit: 10 F fixed; Low limit/circulator: 10 F to 25 F adj. |
Timing | Safety Switch-- 45 sec |
Anticipator Setting | 0.2 A |
Insulation Depth (in.) | 1 1/2 in. |
Insulation Depth (mm) | 38 mm |
Electrical Ratings, Ignition | 360 VA |
Electrical Ratings, Burner | At Full Load-- 4.4 A @ 120 Vac; At Locked Rotor-- 26.4 A @ 120 Vac |