Product Description
DUNKIRK PILOT 146-62-092Overview
The Q3451 Intermittent Pilot Burners provide pilot flame ignition and sensing for intermittent ignition systems. They consist of a pilot burner with a single rod combination spark igniter/flame sensor, orifice assembly, and compression fitting.
Features
- Single-rod Pilot Burner/Igniter Sensors have an integral cable and bent rod that sparks to hood.
- Natural and LP gas orifices available.
- Variety of target styles available.
- Variety of mounting brackets available.
Â
Product Specifications | |
Application | Pilot Burner |
Used With | S8600 |
Mounting | Bracket Style B |
Approvals, Underwriters Laboratories Inc. | UL Listed: File no. MP9928, Guide no. MCUR2 |
Temperature Ratings (C) | Leadwire --250 C |
Type of Gas | Natural |
Approvals, Canadian Gas Association | CGA Certified: 1029-AB-8865 |
Approvals, American Gas Association | AGA Design Certificate: L2025001 |
Aeration | Non-primary |
Compression Fitting Size | 1/8 in. |
Compression Fitting Length | 1 1/4 in. |
Orifice | BCR-18 (0.018 in.) |
Tip Style | Single |
Direction of Front Tip | (F) Front |
Dual Rod or Single Rod | Single Rod |
Pilot Btuh | 1000 |
Length (in.) | Ignition Wire--36 in. |
Length (mm) | 914 mm |