Product Description
Honeywell C6097A1038 Pressure Switch 1/4" NPT ManualOverview
Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure systems.
Features
- For use with natural gas, liquid propane (LP) gas, or air.
- Diaphragm-actuated safety-limit switch.
- Switch can be wired to turn on alarm.
- C6097A models break control circuit at setpoint on pressure fall.
- C6097B models break control circuit at setpoint on pressure rise.
- Lockout with manual reset and recycle options.
- Lockout models have external manual reset button.
- Removable transparent cover protects scaleplate and adjusting knob.
- Pipe tappings allow selection of positive pressure (air only) or venting connections (NPT mount only).
- 1/4 in. NPT or flange mount models for direct mounting to Honeywell Integrated Valve Train.
- Optional switch position indicator lamp available.
- IP54 enclosure standard.
- Ranges: 0.4 to 5 in.wc, 3 to 21 in.wc, 12 to 60 in.wc or 1.5 to 7 psi.
- Surge orifice.
- Integral vent limiter on all models.
Product Specifications | |
Application | Safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes |
Dimensions (in.) | 3 17/32 in. high x 2 23/32 in. wide x 2 23/32 in. deep |
Dimensions (mm) | 90 mm high x 69 mm wide x 69 mm deep |
Mounting | 1/4 in. NPT internal thread |
Electrical Ratings | Ignition Transformer: 540 VA, Pilot Valve: 50 VA. Main Valve: 400 VA with 2-1/2 times inrush |
Approvals, Underwriters Laboratories Inc. | Component Listed, MP 2168-8-1 |
Approvals, Canadian Standards Association | File # 95329 Certificate 2632-01 |
Electrical Connections | Screw terminals |
Contact Ratings | 120 Vac Switch Contact-- 3.0 AFL, 18.0 ALR, 5.0 A resistive; 240 Vac Switch Contact-- 3.0 AFL, 18.0 ALR, 5.0 A resistive |
Operating Temperature Range (F) | -40 F to +140 F |
Operating Temperature Range (C) | -40 C to +60 C |
Approvals, Swiss RE | Acceptable |
Approvals, Factory Mutual | JI 2D4A1.AF |
Approvals, Others | CSD-1 AFB: Acceptable |
Operating Range (psi) | 12 to 60 in. wc |
Operating Range (kPa) | 3.0 to 15 kPa |
Differential Pressure Range (psi) | max. 10 in. wc @ min. setpoint; max. 12 in. wc @ max. setpoint |
Differential Pressure Range (kPa) | max. 2.5 kPa @ min. setpoint; max. 3.0 kPa @ max. setpoint: |
Differential Type | Additive |
Switch Operation | Manual Reset |
Switching Action | Break on pressure fall |
Pipe Connection | Vent or Low pressure--1/8 in. NPT internal thread |