Description: Furnace Control Control - replacement for Carrier CES0110074-00/01 control boards Low cost form, fit and functional replacement for Carrier: CES0110074-01 Hot Surface Ignition (HSI) control board Microprocessor-based Controls vent motor and blower control Monitors limit switch, pressure switch and gas valve 100% lockout safety feature Compatible with LP or Natural Gas Status LED for fault codes to aid in troubleshooting ReplacesCarrier: CES0110074-00, CES0110074-01 Specifications: Electrical:- Line Voltage Range: 98-132 VAC @ 60Hz - Cool Blower: 20A, 2 HP, 240 VAC - Heat: 10A, 240 VAC - Inducer Motor: 4A FLA, 8A LRA @ 120 VAC  Timing: - Inducer Pre-Purge Time: 1 second - Heat Blower On Delay: 45 seconds - Heat Blower Off Delays: 120 or 180 second - Cool Blower On Delay: 1 second - Cool Blower Off Delay: 1 secondÂ