Description: Intermittent ignition oil primary control with 15-second safety timing; replacement for Honeywell R8184G Series Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat Solid state flame sensing circuit LED on terminal strip indicates system lockout Enclosed safety switch with external reset button Mounts on standard 4x4 J-Box (select models may be mounted directly on burner housing) C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required Replacement for popular competitive models Specifications: Ignition Type: Intermittent Timing, Safety Switch: 15 Mounting Bracket: Standard 4x4 J-Box or direct mounting on burner housing  Electrical Rating (Contacts - Full Load): 7.4 A @ 120 VAC 3.7 A @ 240 VAC  Electrical Rating (Contacts - Locked Rotor): 44.4 A @ 120 VAC 22.2 A @ 240 VAC  Temperature Range: -30°F to 130°F  Approvals: UL Approved Weight/Dimensions: Weight: 0.95 Height: 2.35 Width: 4.08 Length: 4.41ReplacesHoneywell: R8184G4066, R8184G1161, R8184G1294Â