Overview Gas valves for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 20 to 200 cfh. Product Specifications ApplicationSingle Stage Dimensions (in.)5 3/16 in high x 4 1/8 in. wide x 3 1/4 in. deep Dimensions (mm)132 mm high x 104 mm wide x 83 mm deep IncludesNatural to LP Conversion Kit; Q340 Thermocouple; One 1/2" x 3/8" reducer bushing; One 3/4" straight flange Item TypeProduct Mounting0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. Frequency60 Hz Approvals, Underwriters Laboratories Inc.UL Component Recognized MCCZ2.MH5323 Approvals, Canadian Standards Association112395 Electrical ConnectionsCombination screw and 1/4 in. male quick connects. Voltage24 Vac Operating Temperature Range (F)0 F to 175 F Operating Temperature Range (C)-18 C to +79 C Body PatternStraight-through Opening CharacteristicsStandard Pressure Ratings (psi)1/2 psi Pressure Ratings (kPa)3.5 kPa Inlet/Outlet Size (in.)1/2 in. x 1/2 in. Pilot Gas OutletCompression fitting for 1/4 in. OD tubing Pressure Tapping1/8 in. NPT with plug Type of FuelNatural Capacity (kBtuh)At 1 in. wc p.d.-- 130,000 BTUh: 20,000 BTUh minimum Approvals, Australian Gas Association4717 Pressure Regulator Setpoint (in. wc)3.5 in. wc Pressure Regulator Setpoint (kPa)0.87 kPa Ignition TypeStanding Pilot Anticipator Setting0.5 A