Honeywell SV9510M2511 Direct Hot Surface Ignition SmartValveĀ® Control. Standard Opening. Set 3.5" WC. 17 sec HSI Warm-Up.Overview
The SV9510 SmartValveĀ® System Controls, combine gas flow control and electronic direct main burner ignition sequencing functions into a single unit and provide all gas ignition safety functions by controlling gas flow, ignition source and air blower.
Features
- The control communicates directly with the ST9160 Electronic Fan Timer (EFT) in typical forced warm air furnace applications.
- It will also interface with the 208907 Terminal Board, providing compatibility with power-stealing thermostats. Or, it directly interfaces with the appropriate power supplies and a system thermostat for additional appliance applications.
- When controlled directly by a thermostat, the control does not provide a postpurge function, as power to the control is removed when the thermostat call for heat ends.
- This system is suitable for a wide range of fan-assisted combustion, gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.
Product Specifications | |
Dimensions (in.) | 3.2 in. wide x 4.9 in. high x 4.1 in.long |
Dimensions (mm) | 81 mm wide x124 mm high x 104 mm long. |
Includes | LP Conversion Kit |
Mounting | 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. |
Electrical Ratings | 24 Vac |
Frequency | 50 Hz; 60 Hz |
Tradeline Value | Super Tradeline |
Voltage | Call for heat--24 Vac, 60 Hz |
Flame Failure Response Time (sec) | 2 sec @ 5 ĀµA |
PrePurge | 15 seconds |
Ambient Temperature Range (F) | -40 F to +175 F |
Ambient Temperature Range (C) | -40 C to +79 C |
Ignition System Type | Direct Hot Surface Ignition |
Ignition Sequence | 17/27 sec |
Type of Gas | Natural |
Flame Sense | Two Rod |
Ignition Trials To Lockout | 4 trials |
Ignition Trial Time (sec) | 7 sec |
Body Pattern | Straight-through |
Opening Characteristics | Standard Opening |
Pressure Regulator Setting (psi) | 3.5 in. wc |
Pressure Regulator Setting (kPa) | 0.87 kPa |
Pressure Ratings (psi) | 1/2 psi |
Pressure Ratings (kPa) | 3.5 kPa |
Inlet/Outlet Size (in.) | 1/2 in. NPT x 1/2 in. NPT |
Capacity (ftĀ³/hr) | Maximum at 1 in. P.D.--150 ftĀ³/hr; Maximum--200 ftĀ³/hr; Minimum--20 ftĀ³/hr |
Capacity (mĀ³/hr) | Maximum at 1 in. P.D.--4.2 mĀ³/hr; Maximum--5.7 mĀ³/hr; Minimum--0.6 mĀ³/hr |
Pressure Tapping | 1/8 in. - NPT |