Product Description
Incldues
- Dual-Temperature Accessory - ATH4
- (2) K-type Wrap Tab Bead Thermocouples - ATB1
- (2) Velcro Tie- wraps (not pictured)
- Mini-calibration Screwdriver
- 9V Battery (installed)
- Operator’s Manual
The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters. Use wet and dry bulb thermocouples to find target superheat.
Designed for HVAC/R, the Dual-Temperature Accessory, model ATH4, measures two temperatures and calculatesthe difference in English or metric units.
- Field calibration for ±1ºF accuracy
- Displays ºF directly at 0.1ºF resolution on DMM with 0.1mVDC resolution
- Select ºF or ºC
- Converts from -50ºF to 1800ºF (optional thermocouple required for 1800ºF)
- Includes two “wrap tab” thermocouples plus velcro straps. Thermocouples insulated to 400ºF
- Auto-off can be disabled for data logging